Type: | Self-Starting Diesel Generator |
---|---|
Installation Method: | Fixed |
Stroke: | Four Stroke |
Cooling Method: | Water Cooling |
Output Type: | AC Three Phase |
Speed: | Speed |
Samples: |
---|
Customization: |
---|
Suppliers with verified business licenses
THE FOLLOWING ENGINE, ALTERNATOR AND CONTROLLER BRANDS FOR OPTIONS
PRIME POWER | ENGINE | ALTERNATOR | CONTROLLER |
25kVA - 1500kVA | CUMMINS | STAMFORD | DEEPSEA |
9kVA - 2250kVA | PERKINS | GENLITEC | COMAP |
20kVA - 560kVA | DEUTZ | LEROY SOMER | SMARTGEN |
250kVA - 3000kVA | MTU | MECC ALTE | |
10kVA - 38kVA | KUBOTA | ENGGA | |
20kVA - 180kVA | LOVOL | MARATHON | |
150kVA - 750kVA | DOOSAN | ||
85kVA - 730kVA | Volvo | ||
10kVA - 250kVA | RICARDO | ||
10kVA - 2500kVA | CATERPILLAR GENERATORS | ||
10kVA - 2500kVA | Chinese BRAND |
Factory Directly 500kw 600kw 720kw 800kw Cummins Engine Diesel Generator Set
Δ STANDARD CONFIGURATION
1) Powered by original CUMMINS water-cooled diesel engine.
2) Cummins diesel engine and Stamford alternator with global warranty.
3) STAMFORD Single bearing alternator with insulation class H and IP23.
4) Standard CHINT or DELIXI circuit breaker, ABB as an optional.
5) Steel base fuel tank with anti-vibration mounting.
6) Based at leaset 8 hours build-in fuel tank ensure daily use.
7) Industrial 9 dB muffler exhaust system, free-maintenance battery, complete set of user's manual.
8) Flexible fuel lines and lube oil, water & fuel drain cocks.
9) Standard SMARTGEN HGM420/HGM6110/HGM6120 antomatic start digital controller.
10) Original CUMMINS 50ºC full protection radiator.
10) Standard Shrink wrap packing method (Plywood packing box as optional).
Δ TESTING ITEMS
GENLITEC POWER provides a full line of brand new and high quality products.
Each and every unit is strictly factory tested before shipment.
1) Parts faults testing
2) Fuel tank pressure testing
3) Bolt tightening torque testing
4) Painting thickness testing
5) Voltage bearing and insulation testing
6) Noise testing
7) Loading Testing: 25%, 50%, 75%, 100%, 110% load to check verify that all control systems, alarm and shut-down protection.
Gensets model | GPC750(S) | ||||||
Prime power | 750kVA/600KW | ||||||
Standby power | 825kVA/660KW | ||||||
Rated Voltage | 220V/380V | ||||||
Rated frequency(Hz) | 50Hz | ||||||
Rated Speed | 1500rpm | ||||||
Power Factor(COS) | 0.8(lagging) | ||||||
Dimensions of opne type(mm) (L×W×H) | 4250*1730*2500 | ||||||
Net weight(open type) (kg): | 6600 | ||||||
DIESEL ENGINE TECHNICAL DATA | |||||||
Engine brand | Powered by Cummins | ||||||
Engine model | KTA38-G2 | ||||||
Number of Cylinders | 12 | ||||||
Cylinder arrangement | "V" | ||||||
Cycle | Four stroke | ||||||
Aspiration | Turbo charged | ||||||
Bore×Stroke (mm×mm) | 159X 159 | ||||||
Displacement (Liter) | 37.8L | ||||||
Compression Ratio | 14.5: 1 | ||||||
Speed Governor | Electronic | ||||||
Cooling System | Water-cooling | ||||||
Starting Method | DC24V electrical starting | ||||||
ALTERNATOR TECHNICAL DATA | |||||||
Alternator brand | STAMFORD | ||||||
Alternator model | LVI634B | ||||||
Number of Phase | 3 | ||||||
Connecting Type | 3 Phase and 4 Wires | ||||||
Number of Bearing | 1 | ||||||
Protection Grade | IP23 | ||||||
Altitude | ≤1000m | ||||||
Exciter Type | Brushless, Self-exciting, AVR automatic voltage regulating, 100% Copper winding wire | ||||||
Insulation Class | H | ||||||
Telephone Influence Factor (TIF) | ≤50 | ||||||
THF | ≤2% | ||||||
Voltage Regulation, Steady State | ≤±1% | ||||||
Transient State Voltage | ≤-15%~+20% |
Exhaust silencer | Flexible pipes | Flange | Base frame | Main circuit breaker |
Starting battery | Battery wires | Battery charger | Float battery charger | AVR |
Cooling radiator | Wires diagram | Manual books | Auto control panel | Silent canopy |
Engine & Radiator | Alternator part | Electric part | Fuel tank part | Others |
Water preheater | PMG | ATS | External daily fuel tank | Weatherproof canopy |
Lub oil pre-heater | Anti-condensation heater | Synchronization panel | Automatic fuel pump | Mobile trailer |
Spare parts | Parallel droop | ABB breaker | Oil drain pump | Containerized |
MODEL | PRIME POWER | STANDBY POWER | ENGINE | VOLTAGE | FREQUENCY | GOV. | ||
KW | kVA | KW | kVA | CUMMINS | V | Hz | ||
GPC25(S) | 20 | 25 | 22 | 28 | X2.5G2 | 230/400 | 50 | E |
GPC28(S)-I | 22 | 28 | 24 | 30 | 4B3.9G1 | 230/400 | 50 | M |
GPC28(S)-II | 22 | 28 | 24 | 30 | 4B3.9G2 | 230/400 | 50 | E |
GPC40(S)-I | 32 | 40 | 35 | 44 | 4BT3.9G1 | 230/400 | 50 | M |
GPC40(S)-II | 32 | 40 | 35 | 44 | 4BT3.9G2 | 230/400 | 50 | E |
GPC50(S) | 40 | 50 | 44 | 55 | 4BTA3.9G2 | 230/400 | 50 | E |
GPC60(S) | 48 | 60 | 53 | 66 | 4BTA3.9G2 | 230/400 | 50 | E |
GPC80(S) | 64 | 80 | 70 | 88 | 4BTA3.9G11 | 230/400 | 50 | E |
GPC100(S) | 80 | 100 | 88 | 110 | 6BT5.9G2 | 230/400 | 50 | E |
GPC113(S) | 90 | 113 | 99 | 124 | 6BTA5.9G2 | 230/400 | 50 | E |
GPC125(S) | 100 | 125 | 110 | 138 | 6BTAA5.9G2 | 230/400 | 50 | E |
GPC138(S) | 110 | 138 | 121 | 151 | 6BTAA5.9G2 | 230/400 | 50 | E |
GPC150(S) | 120 | 150 | 132 | 165 | 6BTAA5.9G12 | 230/400 | 50 | E |
GPC180(S) | 144 | 180 | 158 | 198 | 6CTA8.3G2 | 230/400 | 50 | E |
GPC200(S) | 160 | 200 | 176 | 220 | 6CTAA8.3G2 | 230/400 | 50 | E |
GPC250(S)-I | 200 | 250 | 220 | 275 | 6LTAA8.9G2 | 230/400 | 50 | E |
GPC250(S)-II | 200 | 250 | 220 | 275 | NT855GA | 230/400 | 50 | E |
GPC300(S) | 240 | 300 | 264 | 330 | NTA855G1A | 230/400 | 50 | E |
GPC313(S) | 250 | 313 | 275 | 344 | NTA855G1B | 230/400 | 50 | E |
GPC350(S)-I | 280 | 350 | 308 | 385 | NTA855G2A | 230/400 | 50 | E |
GPC350(S)-II | 280 | 350 | 308 | 385 | NTA855G4 | 230/400 | 50 | E |
GPC375(S) | 300 | 375 | 330 | 413 | NTAA855G7 | 230/400 | 50 | E |
GPC400(S) | 320 | 400 | 352 | 440 | NTAA855G7A | 230/400 | 50 | E |
GPC450(S) | 360 | 450 | 396 | 495 | KTA19G3 | 230/400 | 50 | E |
GPC500(S)-I | 400 | 500 | 440 | 550 | KTA19G3A | 230/400 | 50 | E |
GPC500(S)-II | 400 | 500 | 440 | 550 | KTA19G4 | 230/400 | 50 | E |
GPC600(S) | 480 | 600 | 528 | 660 | KTA19G8 | 230/400 | 50 | E |
GPC650(S) | 520 | 650 | 572 | 715 | QSKTAA19G3 | 230/400 | 50 | E |
GPC750(S) | 600 | 750 | 660 | 825 | VTA28G6 | 230/400 | 50 | E |
GPC800(S) | 640 | 800 | 704 | 880 | KTA38G2B | 230/400 | 50 | E |
GPC900(S) | 720 | 900 | 792 | 990 | KTA38G2A | 230/400 | 50 | E |
GPC1000(S) | 800 | 1000 | 880 | 1100 | KTA38G5 | 230/400 | 50 | E |
GPC1125(S) | 900 | 1125 | 990 | 1238 | KTA38G9 | 230/400 | 50 | E |
GPC1250(S) | 1000 | 1250 | 1100 | 1375 | KTA50G3 | 230/400 | 50 | E |
GPC1400(S) | 1120 | 1400 | 1232 | 1540 | KTA50G8 | 230/400 | 50 | E |
GPC1500(S) | 1200 | 1500 | 1320 | 1650 | KTA50GS8 | 230/400 | 50 | E |
Δ FAQ (FREQUENCY ASKED QUESTION)
Question: What's your warranty period?
Answer: Our payment terms is 1 year or 1000 running hours whichever comes first.
But based on some special project, we can extended our warranty period.
Question: Does your generators has global warranty?
Answer: Yes, most of our products like Cummins, Perkins, Doosan power generator enjoy the global warranty service.
And the alternator we use like Leroysomer, Stamford, marathon also enjoy the global warranty service, so you do not need to worry about the aftersales service.
Question: Do you accept OEM/ODM service?
Answer: Yes, we can accept OEM & ODM service.
Question: What's your payment terms?
Answer: We can accept T/T 30% in advance, and the balance 70% shall be paid before shipment.
Or 100% irrevocable confirmed L/C at sight.
Question: What's your delivery time?
Answer: Our normal delivery time is 15 - 25 working days.
But if your order is some special engine and alternator, then the delivery time is longer.
Question: What's the MOQ?
Answer: 1 Set.